0-100kVac,1kVA resistive load:10mA 3kVA capacitive load: up to 30 mA @ 100kV with tuned load, output current is reduced at lower voltages
Duty:
3kVA:1hour ON,1hour OFF 1.5kVA:continuous
Kilovoltmeter:
3.5″,Scaled 0-50/100kVac,±2% F.S.
Currentmeter:
3.5″,Scaled 0-1.0mAac,±2% F.S. with range multipliers of x1,x10and x100 Guard/Ground Load Return
Distortion:
Less than 5%
Case Dimensions
21″w x 11.25″d x 15.25″h,35lbs.
and Weight:
534mm w x 286mm d x 387mm h,16kg
HV Tank Dimensions
13″w x 13″d x 22″h,85lbs.
and Weight:
330mm w x 330mm d x 559mm h,39kg
*Options:
The PFT-1003CM AC Hipot can be upgraded to include a fault burning circuit, and for increased portability. A hand cart is also available.
For further information, please contact us.
DC Hipot & Megohmmeter Test Sets – PTS Series The PTS Series of DC hipots are combination high voltage DC proof testers, or hipots, and high voltage Megohmmeters. Hipoting, or leakage current measurement, and insulation resistance testing can now be performed with one instrument. Our DC testers range from 37.5 kV to 300 kV.These products are among the most portable and affordable DC hipots available and offer features and advantages not found elsewhere: • +/-1% input voltage regulator on some models • Anti-static glass front meters • Rugged and transit protected meters • Five range current meter with 0 – 1uA low scale • 10 mA continuous duty output rating most models • Internal HV shorting solenoid with discharge resistor • Rugged, field proven construction